Opens in a new tab
Become our Distributor

Concrete spacer PCA-90

barcode_scanner Item code
: PCA-90
target Used for
: Thép lớp trên
shield_locked Concrete cover
: 90mm
weight Breaking load
: 3,5 KN
box Packing
: 60 pcs/box
CHAT WITH US
DISTRIBUTOR
Sample Request
category GROUP
Concrete spacer PCA-90
Concrete spacer PCA-90
Concrete spacer PCA-90
Concrete spacer PCA-90

1. SPECIFICATIONS OF Concrete spacer PCA-90

arrow_right Name
: Concrete spacer PCA-90
arrow_right PCS / carton
: 60 pieces
arrow_right Carton weight
: 19,5kg
arrow_right Pallet Gross Dims
: 1125 x 1130 x 1070 mm
arrow_right Cartons per pallet
: 96
arrow_right Container 20 feet
: 10 pallet
arrow_right Item code
: PCA-90
arrow_right Brand
: PRECA
arrow_right Manufacturer
: Preca Corporation
arrow_right Material
: Concrete
arrow_right Used for
: Top rebar
arrow_right Breaking load
: 3,5 KN
arrow_right Concrete cover
: 90mm
arrow_right Packing
: Carton
arrow_right Carton size
: 300 × 180 × 245 mm

2. OVERVIEW – WHAT IS THE 90MM H-SHAPED CONCRETE SPACER PCA-90?

The 90mm H-shaped concrete spacer PCA-90 is a specialized product designed to support and maintain the top rebar layer at a height of 90mm. Unlike bottom layer spacers that create clearance to the formwork, the H-shaped series functions to maintain the distance between rebar layers and prevent the top steel mesh from sagging or lowering during construction. The distinct application feature of PCA-90 is serving top rebar layers requiring a 90mm elevation, acting as a transition level between the H80 group and the 100mm high group. The product height must be verified against the structural element thickness, the elevation of the two rebar layers, and rebar layout drawings; do not use this model to replace bottom cover spacers unless permitted by design specifications.

3. KEY FEATURES AND STRUCTURE

The H-shape creates two support legs and a central connecting body, helping PCA-90 stand stably in the vertical orientation and provide a working height of 90mm. The top surface acts as the support area for top rebar bars or mesh, while the legs transfer loads to the supporting layer beneath. The key difference of PCA-90 is serving top rebar layers requiring a 90mm elevation, acting as a transition level between the H80 group and the 100mm high group. As the height increases, requirements for controlling vertical alignment, layout density, and securing connections to the steel mesh also increase to prevent overturning or tilting during worker movement and concrete pouring. The product is monolithically cast from concrete, making it suitable to remain embedded within the structural element. The role of the H-shaped spacer is to maintain the elevation of the top rebar layer, rather than directly determining the bottom cover under the formwork. All application locations must be based on slab or footing thickness, rebar diameter, and approved construction methods.

4. USER GUIDE

1. Check technical drawings to confirm the required height between rebar layers and verify that model PCA-90 corresponds to 90mm. 2. Place the H-shaped spacer vertically on a stable surface or support layer; position the top rebar into the designated load-bearing area. 3. Secure the rebar mesh and spacer as necessary to prevent tipping, tilting, or height loss during site movement. 4. Verify the flatness and elevation of the top rebar mesh prior to concrete placement. The placement density depends on rebar diameter, mesh spacing, spacer height, and construction loads. Taller spacer models require more cautious layout; reinforce at edges, rebar lap splices, material transport pathways, or areas prone to mesh sagging.

5. INSPECTION AND QUALITY CONTROL

1. Check technical drawings to confirm the required height between rebar layers and verify that model PCA-90 corresponds to 90mm. 2. Place the H-shaped spacer vertically on a stable surface or support layer; position the top rebar into the designated load-bearing area. 3. Secure the rebar mesh and spacer as necessary to prevent tipping, tilting, or height loss during site movement. 4. Verify the flatness and elevation of the top rebar mesh prior to concrete placement. The placement density depends on rebar diameter, mesh spacing, spacer height, and construction loads. Taller spacer models require more cautious layout; reinforce at edges, rebar lap splices, material transport pathways, or areas prone to mesh sagging.

PRECA Consultant
phone_in_talk 0933 130 035
HO CHI MINH CITY
QL1K, Tan Dong Hiep, Ho Chi Minh City
CENTRAL REGION
33 Dong Da, Quy Nhon, Gia Lai
Please enter your delivery address, and Preca will share the nearest authorized dealers with you.

Related Products

Con kê bê tông tròn cọc khoan nhồi 70mm

Concrete spacer PCA-160C

Bored pile, Diaphragm wall
barcode_scanner SKU:
PCA-160C
box Quy cách:
20 pcs/box

Concrete spacer PCA-150C

Bored pile, Diaphragm wall
barcode_scanner SKU:
PCA-150C
box Quy cách:
20 pcs/box

Concrete spacer PCA-H10

Top rebar
barcode_scanner SKU:
PCA-H10
box Quy cách:
50 pcs/box

Concrete spacer PCA-80C

Bored pile, Diaphragm wall
barcode_scanner SKU:
PCA-80C
box Quy cách:
70 pcs/box